DocumentCode
3375205
Title
Motion analysis for magnetic resonance myocardial perfusion imaging
Author
Yang, G.Z. ; Gatehouse, P.D. ; Panting, J. ; Burger, P. ; Pennell, D.J. ; Firmin, D.N.
Author_Institution
Magnetic Resonance Unit, R. Brompton Hosp., London, UK
Volume
2
fYear
1997
fDate
14-17 Jul 1997
Firstpage
838
Abstract
The assessment of regional myocardial perfusion using magnetic resonance (MR) imaging during the first-pass of a contrast agent bolus requires tracking of the signal time course for each myocardial segment so that a detailed perfusion map can be derived. To obtain such a map in practice, however, is not trivial because deformation of the shape of the myocardium and respiratory induced motion render a major difficulty in this process. This study describes a practical implementation of a real-time interactive MR echo-planar (EPI) myocardial perfusion imaging system and demonstrates an automated approach for motion and deformation tracking of functional myocardial perfusion images
Keywords
biomedical NMR; contrast agent bolus; deformation; magnetic resonance myocardial perfusion imaging; motion analysis; myocardial segment; myocardium; perfusion map; real-time interactive MR echo-planar myocardial perfusion imaging system; respiratory induced motion; shape; signal time course; tracking;
fLanguage
English
Publisher
iet
Conference_Titel
Image Processing and Its Applications, 1997., Sixth International Conference on
Conference_Location
Dublin
ISSN
0537-9989
Print_ISBN
0-85296-692-X
Type
conf
DOI
10.1049/cp:19971014
Filename
615646
Link To Document