• DocumentCode
    3376400
  • Title

    Horizontal component of electric field due to lightning return strokes

  • Author

    Chandrasekaran, K. ; Punekar, Gururaj S.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Nat. Inst. of Technol. Karnataka, Mangalore, India
  • fYear
    2011
  • fDate
    22-24 Dec. 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Lightning generated horizontal electric field above the ground have been computed and reported for a typical height of 10 m (above the ground plane), at a radial distance of 750 m from the striking point. The results are presented for typical first and subsequent return strokes of lightning involving two cases, (i) perfectly conducting ground (ii) finitely conducting ground (σg = 0.0001 S/m). The ground conductivity effects on the horizontal electric field components (static, induction and radiation) are studied. A comparison is made on the basis of computed results with typical first and subsequent strokes.
  • Keywords
    earthing; electric fields; lightning; conducting ground; distance 10 m; distance 750 m; finitely conducting ground; ground conductivity effect; lightning generated horizontal electric field component; lightning return stroke; radial distance; Computational modeling; Conductivity; Electric fields; Electromagnetic compatibility; Lightning; Mathematical model; Lightning; groundconductivity; return strokes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Systems (ICPS), 2011 International Conference on
  • Conference_Location
    Chennai
  • Print_ISBN
    INAVLID ISBN
  • Type

    conf

  • DOI
    10.1109/ICPES.2011.6156640
  • Filename
    6156640