DocumentCode
3377325
Title
Characteristics of paper oil insulation by PDC/FDS method
Author
Kumar, A. Ravi ; Kumar, C.H.S. ; Rajan, J. Sundara ; Singh, K.P.
Author_Institution
R&D Manage. Div., Central Power Res. Inst., Bangalore, India
fYear
2011
fDate
22-24 Dec. 2011
Firstpage
1
Lastpage
4
Abstract
Moisture content influences the dielectric properties of paper oil insulation of power transformers. The Polarization/Depolarization current measurements help to understand the dielectric response and conductivity of paper-oil insulation system. This unique concept facilitates the dissipation factor measurement over a wide frequency range. The results provide information on insulation condition such as moisture content in paper oil insulation in both qualitative and quantitative way. This paper discusses the PDC and FDS characteristics of paper oil insulation containing moisture and copper sulphide which is formed due to sulphur in oil.
Keywords
copper compounds; dielectric properties; electric current measurement; electrical conductivity; moisture; paper; power transformer insulation; sulphur compounds; transformer oil; FDS characteristics; PDC characteristics; PDC-FDS method; dielectric conductivity; dielectric properties; dielectric response; dissipation factor measurement; frequency domain spectroscopy; moisture content; paper-oil insulation system; polarization-depolarization current measurement; power transformer insulation; Copper; Dielectrics; Frequency measurement; Moisture; Oil insulation; Power transformers; Copper corrosion; Copper sulphide; FDS; PDC; paper-oil insulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Systems (ICPS), 2011 International Conference on
Conference_Location
Chennai
Print_ISBN
INAVLID ISBN
Type
conf
DOI
10.1109/ICPES.2011.6156692
Filename
6156692
Link To Document