• DocumentCode
    3377325
  • Title

    Characteristics of paper oil insulation by PDC/FDS method

  • Author

    Kumar, A. Ravi ; Kumar, C.H.S. ; Rajan, J. Sundara ; Singh, K.P.

  • Author_Institution
    R&D Manage. Div., Central Power Res. Inst., Bangalore, India
  • fYear
    2011
  • fDate
    22-24 Dec. 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Moisture content influences the dielectric properties of paper oil insulation of power transformers. The Polarization/Depolarization current measurements help to understand the dielectric response and conductivity of paper-oil insulation system. This unique concept facilitates the dissipation factor measurement over a wide frequency range. The results provide information on insulation condition such as moisture content in paper oil insulation in both qualitative and quantitative way. This paper discusses the PDC and FDS characteristics of paper oil insulation containing moisture and copper sulphide which is formed due to sulphur in oil.
  • Keywords
    copper compounds; dielectric properties; electric current measurement; electrical conductivity; moisture; paper; power transformer insulation; sulphur compounds; transformer oil; FDS characteristics; PDC characteristics; PDC-FDS method; dielectric conductivity; dielectric properties; dielectric response; dissipation factor measurement; frequency domain spectroscopy; moisture content; paper-oil insulation system; polarization-depolarization current measurement; power transformer insulation; Copper; Dielectrics; Frequency measurement; Moisture; Oil insulation; Power transformers; Copper corrosion; Copper sulphide; FDS; PDC; paper-oil insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Systems (ICPS), 2011 International Conference on
  • Conference_Location
    Chennai
  • Print_ISBN
    INAVLID ISBN
  • Type

    conf

  • DOI
    10.1109/ICPES.2011.6156692
  • Filename
    6156692