Title :
Aspects of GTEM to OATS measurement correlation
Author :
Nothofer, A. ; Marvin, A.C.
Author_Institution :
Dept. of Electron., York Univ., UK
Abstract :
The GTEM cell is a broadband transverse electromagnetic waveguide working up to 1 GHz. The OATS is the standard environment for emission measurements. GTEM cell data have to be correlated to the OATS results. This paper describes two methods of performing this correlation and investigates their performance. Measurements in a GTEM cell and on an OATS have been taken and the results have been compared. Special attention is given to problems associated with the reduction of the measurement effort
Keywords :
electromagnetic interference; 1 GHz; EMI; GTEM cell; GTEM cell data; GTEM measurement correlation; OATS measurement correlation; OATS results; UHF; broadband transverse electromagnetic waveguide; emission measurements; measurement effort reduction; measurement standards; standard environment;
Conference_Titel :
Electromagnetic Compatibility, 1997. 10th International Conference on (Conf. Publ. No. 445)
Conference_Location :
Coventry
Print_ISBN :
0-85296-695-4
DOI :
10.1049/cp:19971139