• DocumentCode
    3378658
  • Title

    Comparing different measurement approaches in a mode-stirred chamber

  • Author

    Petirsch, M. ; Kurner, W. ; Sotriffer, I. ; Schwab, A.

  • Author_Institution
    Inst. of Electr. Eng. & High Voltage Technol., Karlsruhe Univ., Germany
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    929
  • Abstract
    This paper presents the use of a mode-stirred chamber (MSC) for electromagnetic susceptibility (EMS) measurement. The distribution of the field inside the chamber is shown as well as the achievable degree of field homogeneity. The results of the susceptibility measurement by different approaches are compared. The approaches of testing include the mode-tuned and the mode-stirred operation of the MSC and measurements in an anechoic chamber as a reference. A comparison of the results demonstrates a correlation between these approaches
  • Keywords
    UHF measurement; electromagnetic fields; electromagnetic shielding; radiofrequency interference; test facilities; 300 MHz to 1 GHz; electromagnetic susceptibility; field distribution; field homogeneity; measurement approaches; mode-stirred chamber; mode-stirred operation; mode-tuned operation; testing; Anechoic chambers; Contacts; Electric variables measurement; Electromagnetic measurements; Geometry; Medical services; Noise measurement; Q factor; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1999 IEEE International Symposium on
  • Conference_Location
    Seattle, WA
  • Print_ISBN
    0-7803-5057-X
  • Type

    conf

  • DOI
    10.1109/ISEMC.1999.810182
  • Filename
    810182