• DocumentCode
    3378723
  • Title

    Helmholtz coils for MIL-STD-462D RS101 testing

  • Author

    Spencer, Jacob D. ; Davis, Robert H.

  • Author_Institution
    Lockheed Martin Ocean Radar and Sensor Syst., Syracuse, NY, USA
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    940
  • Abstract
    The design of a square Helmholtz coil pair for MIL-STD-462D RS101 radiated susceptibility magnetic field testing is detailed. The square coil shape provides a uniform magnetic field volume that is better suited to typical DUT (device under test) shapes when compared to round coils. The coil pair provides a 30×30×40 inch (76×76×102 cm) test volume. Capacitors are used to resonate the coils and reach the MIL-standard specified test field levels over most of the frequency range
  • Keywords
    coils; electromagnetic compatibility; electronic equipment testing; military standards; test equipment; DUT; Helmholtz coils; MIL-STD-462D RS101 testing; MIL-standard specified test field levels; capacitors; coil resonators; design; device under test; radiated susceptibility magnetic field testing; square coil shape; uniform magnetic field volume; Coils; Frequency; Magnetic fields; Magnetic sensors; Magnetic susceptibility; Oceans; Radar; Sensor systems; Shape; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1999 IEEE International Symposium on
  • Conference_Location
    Seattle, WA
  • Print_ISBN
    0-7803-5057-X
  • Type

    conf

  • DOI
    10.1109/ISEMC.1999.810184
  • Filename
    810184