DocumentCode
3378723
Title
Helmholtz coils for MIL-STD-462D RS101 testing
Author
Spencer, Jacob D. ; Davis, Robert H.
Author_Institution
Lockheed Martin Ocean Radar and Sensor Syst., Syracuse, NY, USA
Volume
2
fYear
1999
fDate
1999
Firstpage
940
Abstract
The design of a square Helmholtz coil pair for MIL-STD-462D RS101 radiated susceptibility magnetic field testing is detailed. The square coil shape provides a uniform magnetic field volume that is better suited to typical DUT (device under test) shapes when compared to round coils. The coil pair provides a 30×30×40 inch (76×76×102 cm) test volume. Capacitors are used to resonate the coils and reach the MIL-standard specified test field levels over most of the frequency range
Keywords
coils; electromagnetic compatibility; electronic equipment testing; military standards; test equipment; DUT; Helmholtz coils; MIL-STD-462D RS101 testing; MIL-standard specified test field levels; capacitors; coil resonators; design; device under test; radiated susceptibility magnetic field testing; square coil shape; uniform magnetic field volume; Coils; Frequency; Magnetic fields; Magnetic sensors; Magnetic susceptibility; Oceans; Radar; Sensor systems; Shape; System testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1999 IEEE International Symposium on
Conference_Location
Seattle, WA
Print_ISBN
0-7803-5057-X
Type
conf
DOI
10.1109/ISEMC.1999.810184
Filename
810184
Link To Document