DocumentCode
3384583
Title
Partial discharges on power capacitors
Author
Hantouche, C.
Author_Institution
Electr. de France, Moret-sur-Loing, France
fYear
1992
fDate
7-10 Jun 1992
Firstpage
401
Lastpage
406
Abstract
The author presents a laboratory method for measuring the partial discharges (PDs) on full-size power capacitors used in a network. The PD testing facility, the method considered to be convenient for high capacitance equipment, and the measuring techniques are presented. Tests were carried out on industrial all-film power capacitors. Results of PD measurements before, during and after endurance tests according to the EDF standard are presented
Keywords
electron device testing; life testing; partial discharges; power capacitors; accelerated ageing; all-film dielectric; high capacitance equipment; laboratory method; measuring techniques; overvoltage test; partial discharges; power capacitors; testing facility; Bridge circuits; Capacitance; Electric variables measurement; Insulation; Interference; Partial discharges; Power capacitors; Power measurement; Size measurement; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation, Conference Record of the 1992 IEEE International Symposium on
Conference_Location
Baltimore, MD
ISSN
1089-084X
Print_ISBN
0-7803-0649-X
Type
conf
DOI
10.1109/ELINSL.1992.246972
Filename
246972
Link To Document