• DocumentCode
    3385149
  • Title

    A simple rating method for CPV modules and systems

  • Author

    Araki, K. ; Kemmoku, Y. ; Yamaguchi, M.

  • Author_Institution
    Daido Steel Co., Ltd. 2-30 Daido-cho, Minami, Nagoya 457-8545 Japan
  • fYear
    2008
  • fDate
    11-16 May 2008
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Right now, there is no agreed definition and measurement method for rating concentrator photovoltaic. This paper discusses present situation of the ratings of CPV modules and systems. First, it was analyzed which factors have influence to the performance to CPV modules and systems. Next, the linear interpolation method that is known as a robust estimator especially to multi-junction thin film modules is discussed. The test data was provided from Toyohashi University of Technology where a 550 X CPV module (20 cells connected in series and the total area is 5,445 cm2) was tested independently. The relative standard deviation was 0.89 %, whereas that of the linear interpolation method was 1.2 %. Different from the linear interpolation method, this stratified averaging method is unbiased.
  • Keywords
    Chemicals; Degradation; Impurities; Laboratories; Photovoltaic cells; Photovoltaic systems; Renewable energy resources; Solar power generation; Stability; Stress;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Specialists Conference, 2008. PVSC '08. 33rd IEEE
  • Conference_Location
    San Diego, CA, USA
  • ISSN
    0160-8371
  • Print_ISBN
    978-1-4244-1640-0
  • Electronic_ISBN
    0160-8371
  • Type

    conf

  • DOI
    10.1109/PVSC.2008.4922896
  • Filename
    4922896