Design guidelines for minimum harmonic distortion in a wien oscillator with automatic amplitude control system
Author :
Palumbo, Gaetano ; Pennisi, Melita ; Pennisi, Salvatore
Author_Institution :
DIEES - Dipt. di Ing. Elettr., Elettron. e dei Sist., Univ. of Catania, Catania
fYear :
2008
fDate :
Aug. 31 2008-Sept. 3 2008
Firstpage :
1127
Lastpage :
1130
Abstract :
In sinusoidal oscillators, the nonlinear behavior of the automatic amplitude control mechanism is the main responsible for harmonic distortion. For instance, THD of Wien oscillators with diode-based amplitude control may increase up to 10 dB compared to that of the basic structure. In this paper, THD due to both the operational amplifier and the amplitude stabilization mechanism is analytically evaluated, leading to an optimum design strategy which minimizes distortion. The accuracy and viability of both the proposed analysis and design approach is confirmed experimentally.
Keywords :
circuit stability; harmonic distortion; nonlinear network analysis; oscillators; THD; Wien oscillator; amplitude stabilization mechanism; automatic amplitude control system; diode-based amplitude control; minimum harmonic distortion; nonlinear behavior; operational amplifier; sinusoidal oscillators; Automatic control; Bridge circuits; Control systems; Diodes; Frequency; Guidelines; Harmonic distortion; Nonlinear control systems; Operational amplifiers; Voltage-controlled oscillators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronics, Circuits and Systems, 2008. ICECS 2008. 15th IEEE International Conference on
Conference_Location :
St. Julien´s
Print_ISBN :
978-1-4244-2181-7
Electronic_ISBN :
978-1-4244-2182-4
Type :
conf
DOI :
10.1109/ICECS.2008.4675056
Filename :
4675056
Link To Document :
بازگشت