The Research and Development of Mechanical Vapor Recompression Evaporation Energy-Saving System
Author
Zhang Lin ; Ma ZhiLei ; Xu Chen
Author_Institution
Jiangsu Key Lab. of Oil &Gas Storage & Transp. Technol., Changzhou Univ., Changzhou, China
fYear
2012
fDate
27-29 March 2012
Firstpage
1
Lastpage
4
Abstract
In order to solve the problem of high energy consumption for evaporators, the energy-saving evaporation technology of Mechanical Vapor Recompression (MVR) was purposed in this paper. The enthalpy of the thermal steam compressed by the compressor was increased, and the vapor was used to heat the raw material of the evaporator. The fresh steam is saved and the energy consumption was reduced too. And the energy-saving system of mechanical vapor compression evaporation was researched and developed. It is mainly composed of fluid tanks, preheaters, evaporator, separator, vapor compressor and on-line monitoring and controlled system. In addition, the operating costs were compared between MVR system and the traditional there-efficient evaporator. The results show that the economic benefit of MVR system is more remarkable than traditional there-efficient evaporation.
Keywords
energy conservation; enthalpy; evaporation; MVR evaporation energy-saving system; energy consumption; fluid tanks; fresh steam; mechanical vapor recompression evaporation energy-saving system; on-line monitoring; operating costs; preheaters; raw material; separator; thermal steam enthalpy; Heating; Liquids; Monitoring; Particle separators; Raw materials; Temperature sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Engineering Conference (APPEEC), 2012 Asia-Pacific
Conference_Location
Shanghai
ISSN
2157-4839
Print_ISBN
978-1-4577-0545-8
Type
conf
DOI
10.1109/APPEEC.2012.6307022
Filename
6307022
Link To Document