Title :
An on-site calibration technique for line structured light 3D scanner
Author :
Zhang, Min ; Li, Dehua
Author_Institution :
Inst. for Pattern Recognition & Artificial Intell., Huazhong Univ. of Sci. & Technol., Wuhan, China
Abstract :
We analyze the measuring principle and propose a calibration technique based on perpendicular cross-lines for line structured light 3D scanner. By use of straight line features and perpendicular constraints of the cross-lines, the technique doesn´t require the world coordinates of those feature points on calibration template. The turntable of the 3D scanner rotates with the calibration template. We can takes a number of images of the calibration template from different arbitrary angles. And the intrinsic parameters of the camera can be obtained and further the projection plane parameters can be obtained. Experiments show that the technique has higher accuracy and better robustness. The technique is easy, quick, suited for on-site calibration.
Keywords :
calibration; cameras; 3D scanner; Line structured light; camera calibration; measuring principle; onsite calibration technique; perpendicular cross-lines; projection plane parameters; Calibration; Cameras; Charge coupled devices; Charge-coupled image sensors; Equations; Image reconstruction; Laser modes; Mechanical systems; Mechanical variables measurement; Velocity measurement; Camera calibration; laser projection plane; on-site calibration; perpendicular constraint;
Conference_Titel :
Computational Intelligence and Industrial Applications, 2009. PACIIA 2009. Asia-Pacific Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-4606-3
DOI :
10.1109/PACIIA.2009.5406600