DocumentCode :
3392908
Title :
Low power testing of losses in components for the ITER ECH transmission lines
Author :
Han, S.T. ; Shapiro, M.A. ; Sirigiri, J.R. ; Tax, D. ; Temkin, R.J. ; Woskov, P.P. ; Rasmussen, D.A.
Author_Institution :
Plasma Sci. & Fusion Center, Massachusetts Inst. of Technol., Cambridge, MA
fYear :
2007
fDate :
2-9 Sept. 2007
Firstpage :
934
Lastpage :
936
Abstract :
The transmission lines (TLs) for ITER electron cyclotron heating require extremely low losses, since the 24 MW of power generated by the 170 GHz gyrotrons should be delivered to the plasma with an efficiency of 83% or more. We are developing cold-test techniques to precisely measure the losses in the TL components for ITER, before installation. Experimental results on the measurement of the loss in some TL systems with coherent and incoherent techniques are presented and compared. We report a preliminary measurement of loss in the prototype TL components for the ITER 170 GHz transmission line.
Keywords :
millimetre wave devices; plasma radiofrequency heating; ITER electron cyclotron heating transmission lines; cold-test techniques; frequency 170 GHz; loss measurement; low power testing; power 24 MW; Cyclotrons; Electrons; Heating; Loss measurement; Plasma measurements; Power generation; Power transmission lines; Propagation losses; Testing; Transmission line measurements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Infrared and Millimeter Waves, 2007 and the 2007 15th International Conference on Terahertz Electronics. IRMMW-THz. Joint 32nd International Conference on
Conference_Location :
Cardiff
Print_ISBN :
978-1-4244-1438-3
Type :
conf
DOI :
10.1109/ICIMW.2007.4516799
Filename :
4516799
Link To Document :
بازگشت