DocumentCode
3393411
Title
Consistency of dipole modeling in localization of epileptic foci originating from mesial temporal lobes
Author
Chen, Jia-Jin ; Sheu, Ching-Hwang ; Tsai, Jing-Jane ; Lin, Thy-Sheng
Author_Institution
Inst. of Biomed. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan
Volume
2
fYear
1995
fDate
20-23 Sep 1995
Firstpage
903
Abstract
This research studies the feasibility for noninvasive localization of the epileptic foci originating from mesial temporal area. The consistency of foci localization using dipole modelling for varied montages, including standard 10-20, enhanced temporal electrodes, and combination of invasive sphenoid electrode, were investigated. In addition, a 3-D digitizer was utilized to measure the exact positions of electrodes for accurate head geometrical model and better estimation consistency
Keywords
brain models; electroencephalography; medical signal processing; 3-D digitizer; EEG montages; accurate head geometrical model; dipole modeling consistency; electrodiagnostics; enhanced temporal electrodes; epileptic foci localization; estimation consistency; invasive sphenoid electrode; mesial temporal lobes; Biomedical measurements; Brain modeling; Electrodes; Electroencephalography; Epilepsy; Head; Position measurement; Signal processing; Solid modeling; Temporal lobe;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1995., IEEE 17th Annual Conference
Conference_Location
Montreal, Que.
Print_ISBN
0-7803-2475-7
Type
conf
DOI
10.1109/IEMBS.1995.579262
Filename
579262
Link To Document