• DocumentCode
    3396863
  • Title

    The Simulation of T-F Short-Circuit Fault Location in All Parallel AT Traction Power Supply System Based on the Subsection Impedance Method

  • Author

    Gao, Zhaohui ; Wang, Jiangfeng ; He, Zhengyou

  • Author_Institution
    Sch. of Electr. Eng., Southwest Jiaotong Univ., Chengdu, China
  • fYear
    2012
  • fDate
    27-29 March 2012
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    A deep research on the contact line (T)-negative feeder(F) short-circuit impedance is made in this paper on the basis of analyzing the advantages and disadvantages of all existing parallel AT power supply system fault location methods . Then, the simulation model of the all parallel AT traction power supply system is established and the characteristic of system impedance under T-F short-circuit condition is simulated and analyzed. The results show that the subsection impedance method basically corresponds to the requirement of engineering application. It also provides some theoretical reference for the T-F short-circuit fault analysis of all parallel AT power supply system.
  • Keywords
    electric impedance; fault location; short-circuit currents; traction; T-F short-circuit condition; T-F short-circuit fault analysis; T-F short-circuit fault location simulation; contact line-negative feeder short-circuit impedance; parallel AT power supply system fault location methods; parallel AT traction power supply system; subsection impedance method; Analytical models; Circuit faults; Fault location; Impedance; Impedance measurement; Integrated circuit modeling; Rail transportation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference (APPEEC), 2012 Asia-Pacific
  • Conference_Location
    Shanghai
  • ISSN
    2157-4839
  • Print_ISBN
    978-1-4577-0545-8
  • Type

    conf

  • DOI
    10.1109/APPEEC.2012.6307549
  • Filename
    6307549