Title :
The Simulation of T-F Short-Circuit Fault Location in All Parallel AT Traction Power Supply System Based on the Subsection Impedance Method
Author :
Gao, Zhaohui ; Wang, Jiangfeng ; He, Zhengyou
Author_Institution :
Sch. of Electr. Eng., Southwest Jiaotong Univ., Chengdu, China
Abstract :
A deep research on the contact line (T)-negative feeder(F) short-circuit impedance is made in this paper on the basis of analyzing the advantages and disadvantages of all existing parallel AT power supply system fault location methods . Then, the simulation model of the all parallel AT traction power supply system is established and the characteristic of system impedance under T-F short-circuit condition is simulated and analyzed. The results show that the subsection impedance method basically corresponds to the requirement of engineering application. It also provides some theoretical reference for the T-F short-circuit fault analysis of all parallel AT power supply system.
Keywords :
electric impedance; fault location; short-circuit currents; traction; T-F short-circuit condition; T-F short-circuit fault analysis; T-F short-circuit fault location simulation; contact line-negative feeder short-circuit impedance; parallel AT power supply system fault location methods; parallel AT traction power supply system; subsection impedance method; Analytical models; Circuit faults; Fault location; Impedance; Impedance measurement; Integrated circuit modeling; Rail transportation;
Conference_Titel :
Power and Energy Engineering Conference (APPEEC), 2012 Asia-Pacific
Conference_Location :
Shanghai
Print_ISBN :
978-1-4577-0545-8
DOI :
10.1109/APPEEC.2012.6307549