  • Abstract
    Muscle fiber conduction velocity (MFCV) is now classically encountered in works dealing with neuromuscular assessment. Unfortunately MFCV estimation often presents a large bias essentially due to non-propagated EMG components. This work proposes some ways to optimize the recording methodology in order to limit this drawback. This optimization is simultaneously realized by a specific electrode configuration and an optimal recording location. The results illustrate how the method can be considered as optimal
  • Keywords
    electromyography; medical signal processing; velocity measurement; electrodiagnosis; muscle fiber conduction velocity estimation; neuromuscular assessment; nonpropagated EMG components; optimal recording location; recording methodology; specific electrode configuration; surface EMG analysis; Biomedical measurements; Biomedical monitoring; Delay estimation; Electrodes; Electromyography; Information systems; Laplace equations; Muscles; Pathology; Protocols;