    340257
  • Title

    Comparisons of clinical performance with standard measures of PET cameras

  • Author

    Smith, R.J. ; Karp, J.S.

  • Author_Institution
    Dept. of Radiol., Pennsylvania Univ., Philadelphia, PA, USA
  • Volume
    2
  • fYear
    1998
  • fDate
    1998
  • Firstpage
    1208
  • Abstract
    The NEMA and IEC performance tests of PET cameras provide standard measurements of their intrinsic physical characteristics and the accuracy of corrections applied to them. However the clinical performance of PET cameras are more clearly defined by using patient data with clinical acquisition and processing parameters. Thus, a series of simple patient measurements are proposed to supplement the standard performance measurements. NEMA and clinical measurements are reported here for 3 PET cameras: the UGM 240 H, UGM CPET and HEAD PENN PET cameras. Totals and trues countrates and scatter fractions are compared to 6 liter (20 cm long) and 22 liter (70 cm) cylinder data, while tumor detectability data is used to illustrate the effects of camera resolution and sensitivity. Typical patient images with small tumors are compared to proposed NEMA image quality tests. The accuracy of corrections to the data are assessed from normal organ SUVs and from whole brain blood flow and metabolism measurements. Patient countrates are well reproduced by the 6 liter (brain) and 22 liter (body) cylinder data. However patient activities are typically 40-70% of the activities for peak trues countrates. The patient scatter fractions subtracted are 20% higher than NEMA measurements and patient volumes in the FOV are more than twice that of the 20 cm diameter cylinders. The sensitivity for typical patient studies is indicative of study noise per unit activity in the FOV. Superimposing measured hot sphere contrasts (for 4, 7 and 10:1 data) on a plot of tumor SUV against diameter the authors see the effects of partial volume and tumor metabolism on tumor detectability. These examples illustrate the value of patient measurements in defining clinical PET camera performance
  • Keywords
    biomedical equipment; biomedical measurement; blood flow measurement; brain; cameras; positron emission tomography; tumours; 20 cm; 70 cm; HEAD PENN PET camera; PET cameras; clinical performance comparisons; corrections accuracy; hot sphere contrasts; intrinsic physical characteristics; medical diagnostic imaging; medical instrumentation; metabolism measurements; nuclear medicine; scatter fractions; small tumors; standard measures; tumor detectability data; whole brain blood flow; Biochemistry; Cameras; Head; IEC standards; Measurement standards; Neoplasms; Positron emission tomography; Scattering; Testing; Volume measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
  • Conference_Location
    Toronto, Ont.
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-5021-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1998.774376
  • Filename
    774376