Abstract :
This paper presents a method for calibrating the far-field coaxial pointing error between two types of lasers at target chamber center, which consist of targeting lasers and collimating lasers. The simulation and analysis results show that the method can reduce the coaxial pointing error to less than 0.8μm, thereby enhancing the targeting accuracy.
Keywords :
calibration; laser fusion; ICF; collimating lasers; far-field coaxial pointing error; targeting accuracy; targeting lasers; Analytical models; Charge coupled devices; Laser beams; Laser modes; Laser theory; Optical filters; ICF; coaxial pointing error; insertable filter;