• DocumentCode
    3409127
  • Title

    Force transducer using amorphous Metglas ribbon 2605SC

  • Author

    Hossain, Akram ; Rashid, Muhammed H.

  • Author_Institution
    Dept. of Electr. Eng. Technol., Purdue Univ. Calumet, Hammond, IN, USA
  • fYear
    1988
  • fDate
    2-7 Oct. 1988
  • Firstpage
    1815
  • Abstract
    The authors present the characteristics of a novel type of high-quality strain gage using an amorphous Metglas 2605SC (SC) ribbon. It has been found that when a tensile stress is applied to a piece of SC ribbon, the mutual coupling between the primary and secondary windings changes. The change in the coupling factor is caused by a change in the relative permeability of the material. The magnetic characteristics of this transducer are fully analyzed, the design equations are derived, and a practical design example is given. The theoretical results are compared and shown to agree with the measured values.<>
  • Keywords
    force measurement; strain gauges; strain measurement; Metglas 2605SC; Metglas ribbon; design; force measurement; magnetic characteristics; metallic glasses; mutual coupling; relative permeability; strain gage; tensile stress; transducer; windings; Amorphous magnetic materials; Amorphous materials; Capacitive sensors; Equations; Magnetic analysis; Magnetic materials; Mutual coupling; Permeability; Tensile stress; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Society Annual Meeting, 1988., Conference Record of the 1988 IEEE
  • Conference_Location
    Pittsburgh, PA, USA
  • Type

    conf

  • DOI
    10.1109/IAS.1988.25305
  • Filename