• DocumentCode
    3410450
  • Title

    Hardware Design and System Calibration for Electrical Capacitance Tomography System

  • Author

    Chen, Deyun ; Tang, Wenming ; Wang, Lili ; Yu, Xiaoyang

  • Author_Institution
    Harbin Univ. of Sci. & Technol., Harbin
  • fYear
    2007
  • fDate
    5-8 Aug. 2007
  • Firstpage
    3088
  • Lastpage
    3093
  • Abstract
    The mathematic model of the oil-water two-phase distribution information is established based on double integral infinitesimal principle, an ECT measurement system of 8-electrode oil-water two-phase flow is set up that is comprised of a measurement circuit with stray-capacitance-resistance and a 80C32 SCM, both of which control the measurement among the pole plates and the capture system. The image reconstruction for oil-water two-phase cross-sectional image and the calculating of oil-water two-phase water content can be accomplished by an adaptive threshold image reconstruction algorithm, and the precision of reconstruction is about 1%, which can meet the need of identification of flow regime for oil-water two-phase flow.
  • Keywords
    data acquisition; image reconstruction; two-phase flow; data acquisition; electrical capacitance tomography system; hardware design; image reconstruction; system calibration; two-phase flow; Calibration; Capacitance measurement; Dielectric measurements; Electric variables measurement; Electrical capacitance tomography; Electrodes; Fluid flow measurement; Hardware; Image reconstruction; Pipelines; Data acquisition; Electrical capacitance tomography; Image reconstruction; Two-phase flow measurement; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechatronics and Automation, 2007. ICMA 2007. International Conference on
  • Conference_Location
    Harbin
  • Print_ISBN
    978-1-4244-0828-3
  • Electronic_ISBN
    978-1-4244-0828-3
  • Type

    conf

  • DOI
    10.1109/ICMA.2007.4304054
  • Filename
    4304054