DocumentCode
341098
Title
Electromagnetic transducers close to high temperature plasma in the thermonuclear fusion experiment RFX
Author
Fiorentin, P. ; Peruzzo, S. ; Pomaro, N. ; Sonato, P.
Author_Institution
Consorzio RFX, Padova, Italy
Volume
1
fYear
1999
fDate
1999
Firstpage
285
Abstract
RFX is a magnetically confined fusion experiment in operation since 1992 in Padova (Italy). Analysis of magnetic field is essential for the safe operation of the machine and the understanding of high temperature plasma dynamics. Both of these issues require an accurate electromagnetic diagnostic system. In this paper after a discussion on the problems related to magnetic measurements in fusion experiments, with particular reference to the RFX environment, the probes recently installed inside the vacuum vessel will be described
Keywords
fusion reactor instrumentation; plasma diagnostics; reversed field pinch; transducers; RFX; electromagnetic transducer; high temperature plasma diagnostics; magnetic confinement; magnetic field measurement; reversed field pinch experiment; thermonuclear fusion; Magnetic analysis; Magnetic confinement; Magnetic field measurement; Magnetic variables measurement; Plasma confinement; Plasma diagnostics; Plasma measurements; Plasma temperature; Probes; Transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference, 1999. IMTC/99. Proceedings of the 16th IEEE
Conference_Location
Venice
ISSN
1091-5281
Print_ISBN
0-7803-5276-9
Type
conf
DOI
10.1109/IMTC.1999.776762