• DocumentCode
    341098
  • Title

    Electromagnetic transducers close to high temperature plasma in the thermonuclear fusion experiment RFX

  • Author

    Fiorentin, P. ; Peruzzo, S. ; Pomaro, N. ; Sonato, P.

  • Author_Institution
    Consorzio RFX, Padova, Italy
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    285
  • Abstract
    RFX is a magnetically confined fusion experiment in operation since 1992 in Padova (Italy). Analysis of magnetic field is essential for the safe operation of the machine and the understanding of high temperature plasma dynamics. Both of these issues require an accurate electromagnetic diagnostic system. In this paper after a discussion on the problems related to magnetic measurements in fusion experiments, with particular reference to the RFX environment, the probes recently installed inside the vacuum vessel will be described
  • Keywords
    fusion reactor instrumentation; plasma diagnostics; reversed field pinch; transducers; RFX; electromagnetic transducer; high temperature plasma diagnostics; magnetic confinement; magnetic field measurement; reversed field pinch experiment; thermonuclear fusion; Magnetic analysis; Magnetic confinement; Magnetic field measurement; Magnetic variables measurement; Plasma confinement; Plasma diagnostics; Plasma measurements; Plasma temperature; Probes; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1999. IMTC/99. Proceedings of the 16th IEEE
  • Conference_Location
    Venice
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-5276-9
  • Type

    conf

  • DOI
    10.1109/IMTC.1999.776762
  • Filename
    776762