DocumentCode
3414376
Title
Solenoid Valve Switching Characteristic Test System Design
Author
Song, Xue-ling ; Zhao, Ying-Bao ; Liu, Chao-ying ; Song, Zhe-ying
Author_Institution
Coll. of Electr. Eng. & Inf. Sci., Hebei Univ. of Sci. & Technol., Shijiazhuang, China
Volume
3
fYear
2009
fDate
12-14 Aug. 2009
Firstpage
388
Lastpage
391
Abstract
Respond time is an important parameter for solenoid valve. For some kinds of switching solenoid valve, the respond time is very short and difficult to detect. In this paper, taking a typical hydraulic disc valve as an example it analyzes switching characteristic basing on the opening and closing oil pressure curve of the solenoid valve and gives the opening and closing time calculation method. According to these analyses, a useful time respond characteristic test system is introduced. The whole system design is simple, useful and effective. From the experiment result it can be seen that the system can give the oil pressure curve and respond time accurately.
Keywords
characteristics measurement; hydraulic actuators; solenoids; switching; valves; characteristic test system design; hydraulic disc; oil pressure curve; respond time; solenoid valve switching; Automatic control; Electrical equipment industry; Fuel processing industries; Iron; Magnetic cores; Petroleum; Solenoids; Steady-state; System testing; Valves; Solenoid valve; pressure detection; switching character;
fLanguage
English
Publisher
ieee
Conference_Titel
Hybrid Intelligent Systems, 2009. HIS '09. Ninth International Conference on
Conference_Location
Shenyang
Print_ISBN
978-0-7695-3745-0
Type
conf
DOI
10.1109/HIS.2009.291
Filename
5254602