• DocumentCode
    3416724
  • Title

    Tomographic reconstruction of vascular network from a few projections

  • Author

    Hamon, C. ; Roux, C. ; Coatrieux, J.L. ; Collorec, R.

  • Author_Institution
    Signaux et Images en Medecine, Rennes Univ., France
  • fYear
    1988
  • fDate
    4-7 Nov. 1988
  • Firstpage
    410
  • Abstract
    An investigation is conducted of a tomographic approach to vascular network 3-D reconstruction from incomplete and noisy digital angiography views. The method reconstructs directly the 3-D volume from conic measure projections, using an analytic inversion formula and then, by estimation of vessels supports, eliminates the backprojection artifacts. Reconstruction from thirteen simulated projections demonstrates that even small vessels of three-pixels width can be reconstructed.<>
  • Keywords
    computerised tomography; analytic inversion formula; backprojection artifacts; conic measure projections; digital angiography; tomographic reconstruction; vascular network 3D reconstruction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1988. Proceedings of the Annual International Conference of the IEEE
  • Conference_Location
    New Orleans, LA, USA
  • Print_ISBN
    0-7803-0785-2
  • Type

    conf

  • DOI
    10.1109/IEMBS.1988.94582
  • Filename
    94582