DocumentCode :
3418081
Title :
Study of maximum linear generator output power for Maglev emergency power supply
Author :
Chen, Blin ; Zhou, Dengyan ; Xu, Dehong ; Wu, Xiangming
Author_Institution :
Dept. of Electr. Eng., Zhejiang Univ., Hangzhou, China
Volume :
3
fYear :
2005
fDate :
6-10 March 2005
Firstpage :
2036
Abstract :
This paper presents a novel method of emergent power supply for Maglev when it cannot run. It is realized by injecting a high frequency current to the three phase stator windings and adding an extra linear generator winding to magnetic pole. Output power model of linear generator is given. Relationship between the linear generator output power and the injection harmonic current is studied. Finally, experimental results are given.
Keywords :
electric generators; emergency power supply; harmonics; linear machines; magnetic levitation; stators; Maglev emergency power supply; harmonic current injection; high frequency current; three phase stator windings; Emergency power supplies; Frequency; Magnetic flux; Magnetic levitation; Power generation; Power supplies; Power system harmonics; Stator windings; Switches; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition, 2005. APEC 2005. Twentieth Annual IEEE
Print_ISBN :
0-7803-8975-1
Type :
conf
DOI :
10.1109/APEC.2005.1453339
Filename :
1453339