Title :
Evaluation of Test Reproducibility of Calibration in Reverberation Chamber
Author :
He, Jinliang ; Yuan, Zhiyong ; Zeng, Rong ; Chen, Shuiming ; Zhang, Bo ; Wu, Fan
Author_Institution :
Tsinghua Univ., Beijing
Abstract :
The position of the transmit antenna is analyzed and evaluated according to the measurement data in our developed reverberation chamber. The calibration parameters of the reverberation chamber are also evaluated for different working volumes. The key parameters such as the average normalized electric field and the receive antenna calibration factor are analyzed in detail. It is indicated that the definition of the working volume and the different position of the transmit antenna has a little influence on the test reproducibility of calibrations.
Keywords :
receiving antennas; reverberation chambers; transmitting antennas; average normalized electric field; receive antenna calibration factor; reverberation chamber; test reproducibility evaluation; transmit antenna; Calibration; Electromagnetic interference; Frequency; IEC standards; Medical services; Receiving antennas; Reproducibility of results; Reverberation chamber; Testing; Transmitting antennas;
Conference_Titel :
Electromagnetic Compatibility, 2007. EMC 2007. IEEE International Symposium on
Conference_Location :
Honolulu, HI
Print_ISBN :
1-4244-1349-4
Electronic_ISBN :
1-4244-1350-8
DOI :
10.1109/ISEMC.2007.203