• DocumentCode
    3423208
  • Title

    NIST assessment of uncertainties for standard antenna measurements

  • Author

    Camell, Dennis G. ; Cavcey, Kenneth

  • Author_Institution
    Radio-Frequency Technol. Div., Nat. Inst. of Stand. & Technol., Boulder, CO, USA
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    386
  • Abstract
    The National Institute of Standards and Technology calibrates electromagnetic compatibility reference antennas using the standard antenna method. This method uses a fundamental antenna to precisely measure the electric field. Frequencies of interest are 30 to 1000 MHz. Complete uncertainties are determined for calibrations performed an the open area test site and lead to a statement of uncertainty for the method. The results of this procedure yield a standard uncertainty of 0.4 dB
  • Keywords
    UHF antennas; VHF antennas; calibration; electromagnetic compatibility; measurement uncertainty; receiving antennas; 30 to 1000 MHz; EMC; NIST assessment; electric field; electromagnetic compatibility reference antennas; fundamental antenna; open area test site; standard antenna measurements; standard antenna method; uncertainties; Antenna measurements; Calibration; Electric variables measurement; Electromagnetic compatibility; Electromagnetic measurements; Frequency; Measurement standards; NIST; Open area test sites; Performance evaluation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1999 IEEE International Symposium on
  • Conference_Location
    Seattle, WA
  • Print_ISBN
    0-7803-5057-X
  • Type

    conf

  • DOI
    10.1109/ISEMC.1999.812934
  • Filename
    812934