DocumentCode :
3424692
Title :
Implementation of soft filter damping in control circuitry
Author :
Jin, H.
Author_Institution :
Dept. of Electr. & Comput. Eng., Concordia Univ., Montreal, Que., Canada
fYear :
1992
fDate :
9-13 Nov 1992
Firstpage :
389
Abstract :
Output filters which are used in switching power supplies for reducing switching harmonics have to be properly damped when designing a feedback loop with good performance. A technique that provides filter damping through a control circuit is presented. It is shown that filter damping can be adjusted by incorporating an extra inner current feedback loop. Moreover, in the case of inductive loads, the effective filter damping ratio is directly proportional to the current feedback loop gain. It is also noted that certain functions usually implemented in the power circuit using discrete components can be equally replaced and performed through the control circuit with the same performance and enhanced flexibility. The operating principle of the technique is described, and its performance is evaluated through illustrative examples
Keywords :
damping; feedback; filters; harmonics; load (electric); switched mode power supplies; voltage control; SMPS; control circuit; discrete components; feedback loop; gain; inductive loads; operating principle; output filters; performance; soft filter damping; switching harmonics; switching power supplies; Circuits; Damping; Feedback loop; Inductance; Low pass filters; Magnetic separation; Power harmonic filters; Power supplies; Power system harmonics; Transfer functions;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics, Control, Instrumentation, and Automation, 1992. Power Electronics and Motion Control., Proceedings of the 1992 International Conference on
Conference_Location :
San Diego, CA
Print_ISBN :
0-7803-0582-5
Type :
conf
DOI :
10.1109/IECON.1992.254575
Filename :
254575
Link To Document :
بازگشت