DocumentCode :
3438647
Title :
Failure analysis of integrated detector dewar cryocooler assembly
Author :
Canxiong Lai ; Shaohua Yang ; Guoguang Lu
Author_Institution :
Sci. & Technol. on Reliability Phys. & Applic. of Electron. Component Lab., CEPREI, Guangzhou, China
fYear :
2013
fDate :
15-18 July 2013
Firstpage :
935
Lastpage :
938
Abstract :
The Integrated Detector Dewar Cryocooler Assembly (IDDCA) is a critical component for advanced infrared systems, and especially in infrared (IR) applications, a high reliability for the IDDCA is required increasingly. In this paper, we systematically analyze the failure modes of IDDCA, such as interconnect failure, diodes degradation, vacuum failure, spring fracture, leakage of working medium, mechanical wear and contamination based on their reliability physics. Generally, thermal cycles, outgassing, process defects, are the major causes of these failures. This paper would be helpful for improving the level in the design and manufacture of IDDCA.
Keywords :
contamination; design engineering; failure analysis; fracture; infrared detectors; reliability; springs (mechanical); wear; IDDCA; Integrated Detector Dewar Cryocooler Assembly; advanced infrared systems; contamination; critical component; diode degradation; failure analysis; failure modes; high reliability; infrared applications; interconnect failure; mechanical wear; outgassing; process defects; reliability physics; spring fracture; thermal cycles; vacuum failure; working medium; Assembly; Contamination; Detectors; Indium; Materials; Reliability; Temperature; IDDCA; Infrared Focal Plane Array (IRFPA); cryocooler; dewar; failure mode; reliability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Quality, Reliability, Risk, Maintenance, and Safety Engineering (QR2MSE), 2013 International Conference on
Conference_Location :
Chengdu
Print_ISBN :
978-1-4799-1014-4
Type :
conf
DOI :
10.1109/QR2MSE.2013.6625721
Filename :
6625721
Link To Document :
بازگشت