• DocumentCode
    343994
  • Title

    Diagnostic monitoring of HV stator windings motors and generators

  • Author

    Smith, J.W.R.

  • Author_Institution
    Div. of Syst. of Safety, Mott MacDonald Ltd., Altrincham, UK
  • fYear
    1999
  • fDate
    36251
  • Firstpage
    42401
  • Lastpage
    42404
  • Abstract
    Reliable generation requires the early identification of defects occurring in service. This is best achieved through a planned programme of regular diagnostic testing and is particularly relevant to the electrical insulation of generators and large AC motors. The paper describes diagnostic techniques which can he applied to monitor the in-service condition of stator and rotor windings of generators and large AC motors in and out of service. The paper describes radiofrequency current transformers and partial discharge measurement
  • Keywords
    AC motors; AC motors; HV stator windings; diagnostic monitoring; diagnostic testing; electrical insulation; generators; in-service condition monitoring; partial discharge measurement; radiofrequency current transformers; rotors; stators;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Understanding your Condition Monitoring (Ref. No. 1999/117), IEE Colloquium on
  • Conference_Location
    Chester
  • Type

    conf

  • DOI
    10.1049/ic:19990652
  • Filename
    790282