Abstract
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
With the development of substation automation technology entering the digital era, digital relay protection system become inevitable. Digital protection system has a series of advantages, but its reliability problem had not been concerned also. In this paper, the difference between digital relay protection and the conventional protection had been analyzed firstly, and then the Markov model of full digital protection system had been established, which is for the digital protection system availability. With the calculation formula of availability, the conventional protection system and digital protection system were analyzed.
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
With the development of substation automation technology entering the digital era, digital relay protection system become inevitable. Digital protection system has a series of advantages, but its reliability problem had not been concerned also. In this paper, the difference between digital relay protection and the conventional protection had been analyzed firstly, and then the Markov model of full digital protection system had been established, which is for the digital protection system availability. With the calculation formula of availability, the conventional protection system and digital protection system were analyzed.
Keywords
Markov processes; power system protection; power system reliability; relay protection; Markov model; conventional protection system; digital protection relay system; digital protection system availability; reliability analyses; substation automation technology; Availability; Hardware; Optical fiber cables; Power system reliability; Protective relaying; Substations; digital substation; electronic transformer; relay protection; reliability;
fLanguage
English
Publisher
ieee
Conference_Titel
Quality, Reliability, Risk, Maintenance, and Safety Engineering (QR2MSE), 2013 International Conference on
Conference_Location
Chengdu
Print_ISBN
978-1-4799-1014-4
Type
conf
DOI
10.1109/QR2MSE.2013.6625809
Filename
6625809
Link To Document