• DocumentCode
    3442388
  • Title

    Broken bar detection using inverter currents in induction motor drives

  • Author

    Georgakopoulos, I. ; Mitronikas, E. ; Safacas, A.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Patras, Patras, Greece
  • fYear
    2010
  • fDate
    14-16 June 2010
  • Firstpage
    1030
  • Lastpage
    1035
  • Abstract
    Rotor electrical faults are common types of faults in squirrel cage induction motors and have been investigated in detail in steady state condition for grid-connected induction motors. In this paper, this type of fault is studied in case of inverter driven motors. Inverter input and output currents are studied for the fault indicative frequency components. The harmonics which are induced to the inverter input current give the ability of fault detection under low load and low motor severity fault condition in both motor steady-state and transient operation.
  • Keywords
    fault diagnosis; invertors; squirrel cage motors; broken bar detection; fault indicative frequency components; grid-connected induction motors; inverter currents; inverter driven motors; low motor severity fault condition; motor steady-state operation; motor transient operation; rotor electrical faults; squirrel cage induction motors; Discrete wavelet transforms; Electrical fault detection; Fault diagnosis; Frequency; Induction motor drives; Induction motors; Inverters; Rotors; Stators; Steady-state; Fault diagnosis; induction motors; inverter; spectral analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Electrical Drives Automation and Motion (SPEEDAM), 2010 International Symposium on
  • Conference_Location
    Pisa
  • Print_ISBN
    978-1-4244-4986-6
  • Electronic_ISBN
    978-1-4244-7919-1
  • Type

    conf

  • DOI
    10.1109/SPEEDAM.2010.5542100
  • Filename
    5542100