• DocumentCode
    3443996
  • Title

    Probe Influence on the Measurement Accuracy of Non Uniform LF Magnetic Fields

  • Author

    Bottauscio, O. ; Chiampi, M. ; Crotti, G. ; Zucca, M.

  • Author_Institution
    Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    30
  • Lastpage
    31
  • Abstract
    The error introduced by the coil size averaging effect when measuring non uniform LF magnetic field is analysed with particular reference to the use of field meters equipped with non-concentric coil probes. The analysis is developed by computation and the results are validated by comparison with experimental data
  • Keywords
    magnetic field measurement; measurement errors; probes; coil size averaging effect; error; field meters; magnetic field measurement; measurement accuracy; non uniform LF magnetic fields; nonconcentric coil probes; Coils; Density measurement; Frequency measurement; Magnetic analysis; Magnetic field measurement; Magnetic flux density; Particle measurements; Probes; Shape measurement; Size measurement;