• DocumentCode
    3444056
  • Title

    Intercomparison of Calibration Systems for Ac Shunts up to Audio Frequencies

  • Author

    So, E. ; Angelo, D. ; Tsuchiyama, T. ; Takodoro, T. ; Waltrip, B.C. ; Nelson, T.L.

  • Author_Institution
    Inst. for Nat. Meas. Stand., National Res. Council of Canada, Ottawa, Ont.
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    36
  • Lastpage
    36
  • Abstract
    An intercomparison of calibration systems for ac shunt up to audio frequencies between the National Research Council of Canada, Japan Electric Meters Inspection Corporation, and the National Institute of Standards and Technology, U.S.A., is presented. The transfer standard used for the intercomparison is a 10 A, 0.1 shunt
  • Keywords
    calibration; energy measurement; measurement standards; measurement uncertainty; power measurement; 10 A; AC shunts; Japan Electric Meters Inspection Corporation; National Institute of Standards and Technology; National Research Council of Canada; audio frequencies; calibration systems; Calibration; Councils; Energy measurement; Frequency; Inspection; Laboratories; NIST; Power measurement; Shunt (electrical); Watthour meters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305407
  • Filename
    4097101