DocumentCode
3444100
Title
Towards Accurate Measurement of the Frequency Dependence of Capacitance and Resistance Standards up to 10 MHz
Author
Awan, S.A. ; Kibble, B.P.
Author_Institution
National Phys. Lab., Centre for Electromagn. & Time Metrol.
fYear
2004
fDate
38139
Firstpage
41
Lastpage
42
Abstract
Progress towards an understanding of the frequency dependence of capacitance and resistance standards at frequencies up to 10 MHz is presented. A qualitative comparison is also made for capacitance and resistance measurements between NPL high-frequency four terminal-pair bridge and a commercial impedance analyzer for the first time
Keywords
bridge instruments; capacitance measurement; electric resistance measurement; frequency measurement; measurement standards; capacitance measurements; capacitance standards; frequency dependence; high-frequency four terminal-pair bridge; impedance analyzer; measurement standards; resistance measurements; resistance standards; Bridge circuits; Capacitance measurement; Electrical resistance measurement; Frequency dependence; Frequency measurement; Hafnium; Impedance; Instruments; Measurement standards; Standards development;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2004 Conference on
Conference_Location
London
Print_ISBN
0-7803-8494-6
Electronic_ISBN
0-7803-8494-6
Type
conf
DOI
10.1109/CPEM.2004.305410
Filename
4097104