Title :
Lattice function measurement of FNAL Main Injector at 8-GeV
Author :
Assadi, S. ; Mishra, C.S. ; Tecker, F. ; Yang, M.J.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Abstract :
The commissioning of Fermilab Main Injector had been very successful and the project is at its final phase. Even with the machine working as well as it did plenty of improvements are still to be made. Measuring and to understanding the machine lattice function should eventually lead to the improvement of the machine. In this write-up the preliminary measurement and analysis of the lattice function is reported
Keywords :
accelerator magnets; particle beam dynamics; proton accelerators; synchrotrons; 8 GeV; FNAL Main Injector; lattice function measurement; machine lattice function; preliminary measurement; Apertures; Dispersion; Extraterrestrial measurements; Health information management; Lattices; Least squares methods; Magnetic analysis; Magnetic field measurement; Optical design; Radio frequency;
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location :
New York, NY
Print_ISBN :
0-7803-5573-3
DOI :
10.1109/PAC.1999.792915