Improvement of inner evaporative cooling experiment model for large turbo generator stator bars
Author :
Xiong Bin ; Gu GuoBiao ; Ruan Lin ; Li ZhenGuo ; Fu DePing ; Cao Rui ; Guo ShuQin ; Gao JinShui
Author_Institution :
Univ. of Chinese Acad. of Sci., Beijing, China
fYear :
2013
fDate :
26-29 Oct. 2013
Firstpage :
101
Lastpage :
104
Abstract :
Inner evaporative cooling way of stator bars is generally affected by circulating system and coolant. In this paper, we focus those factors to improve the capability of cooling system. Based on the flowing resistance distribution of system, the structure of components is redesigned to improve the stability and reliability of circulating flow. In the same time, different kinds of coolant are used into the inner evaporative cooling experiment model. The experiment results show that boiling point and viscosity of coolant are the main factors of improvement. The cooling efficiency of hollow strands is improved by new experiment model and coolant, and the structure of improved model and coolant ZF-2 can perfectly satisfy the cooling requirement of 300MW turbo generator.
Keywords :
coolants; cooling; flow instability; reliability; stators; turbogenerators; boiling point; circulating flow reliability; circulating flow stability; circulating system; coolant ZF-2; coolant viscosity; hollow strands; inner evaporative cooling experiment model; large turbo generator stator bars; power 300 MW; resistance distribution; Coolants; Heat transfer; Resistance; Resistance heating; Turbogenerators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2013 International Conference on
Conference_Location :
Busan
Print_ISBN :
978-1-4799-1446-3
Type :
conf
DOI :
10.1109/ICEMS.2013.6754526
Filename :
6754526
Link To Document :
بازگشت