Single magnetic, unity power factor, isolated power converter with ripple free input current
Author
Chen, Wei ; Lee, Fred C.
Author_Institution
Power Electron. Center, Virginia Polytech. Inst. & State Univ., Blacksburg, VA, USA
Volume
2
fYear
1998
fDate
17-22 May 1998
Firstpage
1450
Abstract
The discontinuous conduction mode (DCM) boost or flyback circuit is a low cost solution to meet power factor correction (PFC) requirements. However, large ripple current in the input side requires a large differential mode (DM) filter inductor. For an offline application, a complete power supply design may also need an isolation transformer, increasing size, weight, cost and power loss. This paper proposes a single magnetic, isolated PFC circuit with ripple free input current. The need for a DM filter inductor is therefore eliminated. By using constant duty cycle and constant frequency control, the conventional PWM chip can be adopted for PFC application. The operation principle of the proposed circuit and the design considerations are given in detail. The simulation and experimental results are provided for verification
Keywords
harmonic distortion; power convertors; power factor correction; power filters; power inductors; power system harmonics; PWM chip; constant duty cycle; constant frequency control; conventional PWM chip; design considerations; discontinuous conduction mode; isolated power converter; isolation transformer; power factor correction; power supply design; ripple free input current; Circuits; Costs; Delta modulation; Filters; Inductors; Magnetic separation; Power factor correction; Power supplies; Pulse width modulation; Reactive power;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 1998. PESC 98 Record. 29th Annual IEEE
Conference_Location
Fukuoka
ISSN
0275-9306
Print_ISBN
0-7803-4489-8
Type
conf
DOI
10.1109/PESC.1998.703243
Filename
703243
Link To Document