• DocumentCode
    3446979
  • Title

    Precision Three-Stage 1000 V / 50 Hz Inductive Voltage Divider

  • Author

    Small, G.W. ; Budovsky, I.F. ; Gibbes, A.M. ; Fiander, J.R.

  • Author_Institution
    National Meas. Lab., Lindfield, NSW
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    320
  • Lastpage
    321
  • Abstract
    A separately excited three-stage inductive voltage divider (IVD) has been designed for voltages up to 1000 V at frequencies from 50 to 1000 Hz. The IVD provides output to input voltage ratios of 0.001 and 0.01 with amplitude and in-phase uncertainty of the ratio better than 1times10-6
  • Keywords
    measurement uncertainty; power measurement; voltage dividers; voltage measurement; 1000 V; 50 to 1000 Hz; in-phase uncertainty; three-stage inductive voltage divider; Capacitance measurement; Copper; Current measurement; Impedance; Magnetic cores; Magnetic flux; Magnetic materials; Magnetic shielding; Voltage measurement; Wounds;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305594
  • Filename
    4097249