DocumentCode :
3447060
Title :
Fast resistive attenuators for high accuracy measurements of LI voltages
Author :
Chekurov, Yuri Y. ; Hällström, Jari K.
Author_Institution :
High Voltage Inst., Helsinki Univ. of Technol.
fYear :
2004
fDate :
38139
Firstpage :
328
Lastpage :
329
Abstract :
Design, construction and calibration of compact, inexpensive and fast resistive attenuators for lightning impulse or surge voltage measurements up to 1.5 kV is presented. Estimated uncertainty of attenuator ratio is less than 100 ppm (k=2). The input resistance of attenuators is 50 Omega plusmn 1 % and the rise-time is less than 1 ns. The calibration procedure of the attenuators is described
Keywords :
attenuators; calibration; measurement uncertainty; surges; voltage measurement; calibration; lightning impulses voltages measurement; lightning surge voltage measurement; uncertainty; Attenuation measurement; Attenuators; Calibration; Flanges; Immune system; Lightning; Resistors; Stability; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2004 Conference on
Conference_Location :
London
Print_ISBN :
0-7803-8494-6
Electronic_ISBN :
0-7803-8494-6
Type :
conf
DOI :
10.1109/CPEM.2004.305598
Filename :
4097253
Link To Document :
بازگشت