• DocumentCode
    3447112
  • Title

    Preliminary Experiment of Comparison Between a 1-V NbN-Based Programmable and a Conventional Josephson Array

  • Author

    Murayama, Y. ; Urano, C. ; Iwasa, A. ; Yamamori, H. ; Shoji, A. ; Ishizaki, M.

  • Author_Institution
    National Inst. of Adv. Ind. Sci. & Technol., Ibaraki
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    334
  • Lastpage
    335
  • Abstract
    We tried a direct comparison between a 1-V NbN-based programmable superconductor-normal metal-superconductor (SNS) Josephson array and a conventional superconductor-insulator-superconductor (SIS) Josephson array. In preliminary experiment the voltage difference of the two arrays was -4.3 times 10-9 V in average of 10 measurement sets. The deviation is resulted from the fluctuations of the background in the measurement set
  • Keywords
    Josephson effect; measurement standards; superconducting arrays; superconductor-insulator-superconductor devices; superconductor-normal-superconductor devices; 1 V; NbN; programmable Josephson array; superconductor-insulator-superconductor Josephson array; superconductor-normal metal-superconductor Josephson array; Filters; Fluctuations; Frequency; Helium; Laboratories; NIST; Superconducting devices; Testing; Voltage; Voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305601
  • Filename
    4097256