• DocumentCode
    3447804
  • Title

    Impact of Sensing Area on the Precision of DC Current Measurement using Magnetic Sensor Arrays

  • Author

    Jing, Wang ; Jianjun, Yao ; Jianhua, Wang

  • Author_Institution
    Dept. of Electr. Eng., Xi´´an Jiaotong Univ.
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    402
  • Lastpage
    403
  • Abstract
    Magnetic sensor arrays are proposed to measure the electric current in a non-contact way. In order to achieve higher accuracy, signal processing techniques for magnetic sensor arrays are utilized. As these algorithms don´t take into account the measurement errors caused by the size of the sensing area in the magnetic sensor, further analysis and discussion are necessary to improve the precision of electrical measurement using magnetic sensor array. This paper presents a method to estimate the impact of the sensing area and the error deduction algorithm of magnetic sensor arrays
  • Keywords
    electric current measurement; electric sensing devices; magnetic sensors; measurement errors; sensor arrays; dc current measurement; electric current measurement; error deduction algorithm; magnetic sensor arrays; signal processing techniques; Algorithm design and analysis; Area measurement; Array signal processing; Current measurement; Electric variables measurement; Magnetic analysis; Magnetic sensors; Measurement errors; Sensor arrays; Signal processing algorithms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305278
  • Filename