DocumentCode
3448823
Title
Maximum power point tracking in the PV grid-connected inverters of 5 kW
Author
Salas, V. ; Olias, E.
Author_Institution
Electron. Technol. Dept., Univ. Carlos III de Madrid, Leganes, Spain
fYear
2009
fDate
7-12 June 2009
Abstract
The aim of this article is to describe how closely PV grid-connected inverters operate at the actual maximum power point. To carry this study out six 50 Hz single-phase inverters were selected from European market, around of 5 kW. Each one of them was put into an outdoor grid-connected system installed in Legane¿s (Madrid), Spain. Different electrical signals with respect to irradiance, PV module temperature and local time were measured. DC voltage and maximum power point tracking were analysed.
Keywords
invertors; photovoltaic power systems; power grids; power markets; power system interconnection; European market; Legane¿s; Madrid; PV grid-connected inverters; Spain; frequency 50 Hz; maximum power point tracking; outdoor grid-connected system; power 5 kW; single-phase inverters; Distributed power generation; Impedance; Inverters; Mesh generation; Photovoltaic systems; Pollution measurement; Power generation; Production systems; Solar power generation; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Specialists Conference (PVSC), 2009 34th IEEE
Conference_Location
Philadelphia, PA
ISSN
0160-8371
Print_ISBN
978-1-4244-2949-3
Electronic_ISBN
0160-8371
Type
conf
DOI
10.1109/PVSC.2009.5411698
Filename
5411698
Link To Document