• DocumentCode
    3449665
  • Title

    Improvements in the AC-DC Current Transfer Calibration Capabilities at NRC

  • Author

    Filipski, Piotr S. ; Boecker, Michael

  • Author_Institution
    Inst. for Nat. Meas. Stand., Canada Nat. Res. Council, Ottawa, Ont.
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    579
  • Lastpage
    580
  • Abstract
    NRC Electrical Standards Group is upgrading its shunt calibration facility to offer calibrations up to 100 A at 100 kHz. Primary standards of ac-dc current transfer difference have been verified using fast reversed dc source. A custom set of coaxial shunts has been built and is being characterized
  • Keywords
    calibration; electric current measurement; measurement standards; ac-dc current transfer calibration; coaxial shunts; fast reversed dc source; shunt calibration facility; Analog-digital conversion; Calibration; Councils; Frequency estimation; Frequency measurement; Testing; Thermal resistance; Transconductance; Uncertainty; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305388
  • Filename
    4097382