• DocumentCode
    3449678
  • Title

    Determination of the AC-DC Voltage Transfer Difference of High Voltage Transfer Standards at Low Frequencies

  • Author

    Funck, T. ; Kampik, M. ; Kessler, E. ; Klonz, M. ; Laiz, H. ; Lapuh, R.

  • Author_Institution
    Phys.-Technische Bundesanstalt, Braunschweig
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    581
  • Lastpage
    582
  • Abstract
    The ac-dc transfer difference at low frequencies of thermal converters for higher voltages with planar multijunction thermal converters (PMJTCs) and series resistors has been determined by using only the established linear change of the low-frequency ac-dc current transfer difference of the PMJTC with input power. Uncertainties of less than 1 muV/V are achieved up to 1000V
  • Keywords
    AC-DC power convertors; measurement standards; measurement uncertainty; voltage measurement; PMJTC; ac-dc voltage transfer difference; high voltage transfer standards; measurement standards; planar multijunction thermal converters; Analog-digital conversion; Frequency conversion; Heat transfer; Metrology; Power measurement; Resistance heating; Resistors; Temperature sensors; Thermal resistance; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305389
  • Filename
    4097383