DocumentCode
3450145
Title
Uncertainty Evaluation of a Broadband Attenuation Standard
Author
Lee, Joo-Gwang ; Kim, Jeong-Hwan ; Park, Jeong-Il ; Kang, Ung-Taeg
Author_Institution
Div. of Electromagn. Metrol., Korea Res. Inst. of Stand. & Sci., Daejon
fYear
2004
fDate
38139
Firstpage
620
Lastpage
621
Abstract
We have recently developed a standard step attenuator, composed of 10 steps of build-up chain of power measurement and operating from 10 MHz to 18 GHz. Each step shows a nominal attenuation of about 9 dB and an expanded uncertainty of 0.0018 dB at 30 MHz. The overall system has a dynamic range over 90 dB
Keywords
attenuation measurement; measurement uncertainty; microwave measurement; voltage dividers; 0.010 to 18 GHz; 30 MHz; broadband attenuation standard; step attenuator; uncertainty evaluation; Attenuation measurement; Attenuators; Dynamic range; Frequency; Measurement standards; Mixers; Standards development; Switches; Thermistors; Uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2004 Conference on
Conference_Location
London
Print_ISBN
0-7803-8494-6
Electronic_ISBN
0-7803-8494-6
Type
conf
DOI
10.1109/CPEM.2004.305427