Abstract
An overview of the instrumentation installed in the Fermilab Main Injector is presented. Efficiency, beam loss, average intensity, bunch intensity, position, betatron and synchrotron oscillation frequency, as well as transverse and longitudinal profiles are measured. Systems such as the Beamline Tuner and the Ionization Profile Monitor track changes through the accelerating cycle and analyze their rate of change
Keywords
nuclear instrumentation; particle beam diagnostics; particle beam injection; proton accelerators; storage rings; Beamline Tuner; Fermilab Main Injector; Ionization Profile Monitor; average intensity; beam loss; betatron oscillation frequency; bunch intensity; efficiency; instrumentation; longitudinal profile; position; synchrotron oscillation frequency; transverse profile; Bandwidth; Current measurement; Current transformers; Detectors; Dynamic range; Extraterrestrial measurements; Instruments; Magnetic cores; Monitoring; Position measurement;