The technology of active power factor correction in current critical continuous mode
Author
Yang WenQiang
Volume
1
fYear
1999
fDate
1999
Firstpage
489
Abstract
The paper presents the analysis of a power factor correction circuit employing critical continuous-mode boost converter. The relations between the maximum switching frequency, the maximum switch-off time and the input ranging from VinL to YinH are derived, and the calculating expression of the inductor is proposed. The experiment results show that the analysis is correct
Keywords
DC-DC power convertors; electric current control; power factor correction; active power factor correction; critical continuous-mode boost converter; current critical continuous mode; inductor; maximum switch-off time; maximum switching frequency; Circuits; Inductors; Monitoring; Power factor correction; Power semiconductor devices; Power semiconductor switches; Reactive power; Semiconductor diodes; Switching frequency; Voltage;