  • Abstract
    The hot model for the coupled cavity drift tube linac (CCDTL) resonance control cooling system (RCCS) for the Low Energy Demonstration Accelerator (LEDA) in support of the accelerator production of tritium (APT) is described. Two hydraulic control loops are described that control the frequency in the CCDTL hot model cavity. The two loops supply the required flow to the 32 channels. The control system schema is described to regulate the resonant frequency during steady state operation
  • Keywords
    accelerator control systems; cooling; hydraulic control equipment; ion accelerators; linear accelerators; LEDA; Low Energy Demonstration Accelerator; accelerator production of tritium; coupled cavity drift tube linac; hot model; hydraulic control loops; resonance control cooling system; resonant frequency; Control system synthesis; Cooling; Heat transfer; Linear particle accelerator; Resonance; Resonant frequency; Switches; Temperature control; US Department of Energy; Valves;