DocumentCode
345448
Title
Thermostabilization system of VEPP-5 preinjector
Author
Gubin, K.V. ; Hambikov, V.D. ; Igolkin, A.G. ; Martyshkin, P.V.
Author_Institution
BINP, Novosibirsk, Russia
Volume
2
fYear
1999
fDate
1999
Firstpage
1456
Abstract
Technically the system of thermostabilization supposed to be performed by two-contour water scheme. All elements to be stabilized are connected in parallel to the inner closed water contour. Stabilization of temperature is realized as a controlled heating of input water by the heating unit, individual for each element. Dumping of heat surplus is produced by the heat exchanger. This construction allows to stabilize the cooling water flow through the elements, to decrease the power consumption, to change the individual heating conditions for each element of accelerator to compensate the tolerance in RF parameters during the adjusting process. Main characteristics of the system are shown. At the present time the assembly of water contours is in progress. The heating unit that consists of heater, controlled power supply, flow meter, thermistors and control device, has been completely designed, tested on preinjector prototype and now is in serial production
Keywords
accelerator cavities; booster injectors; electron accelerators; linear accelerators; RF parameters; VEPP-5 preinjector; control device; controlled power supply; cooling water flow; flow meter; individual heating conditions; inner closed water contour; power consumption; thermistors; thermostabilization system; two-contour water scheme; Assembly; Cooling; Energy consumption; Power supplies; Prototypes; Radio frequency; Temperature control; Testing; Thermistors; Water heating;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location
New York, NY
Print_ISBN
0-7803-5573-3
Type
conf
DOI
10.1109/PAC.1999.795580
Filename
795580
Link To Document