• DocumentCode
    345466
  • Title

    Tevatron Run-II beam collimation system

  • Author

    Church, M. ; Drozhdin, A.I. ; Legan, A. ; Mokhov, N.V. ; Reilly, R.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    56
  • Abstract
    Based on realistic Monte-Carlo simulations a two-stage beam collimation system is designed to minimize the beam loss in the Fermilab Tevatron for fixed target and collider Run II. Thin primary collimators are used to increase particle amplitude and their impact parameter on the downstream secondary collimators. This results in a significant reduction of the total beam loss in the machine, decreases collimator overheating and mitigates requirements to collimator alignment. A set of collimators will originally be installed for fixed target operation and for antiproton beam recycling studies. The collimation system improvement will continue into the collider Run II and intensity upgrade
  • Keywords
    Monte Carlo methods; beam handling equipment; colliding beam accelerators; proton accelerators; synchrotrons; Fermilab Tevatron; Monte-Carlo simulations; Tevatron Run-II beam collimation system; antiproton beam recycling; beam loss minimization; collimator alignment; collimator overheating; fixed target; intensity upgrade; total beam loss reduction; two-stage beam collimation system; Accelerator magnets; Colliding beam accelerators; Colliding beam devices; Collimators; Electromagnetic scattering; Magnetic materials; Particle accelerators; Particle beams; Particle scattering; Proton accelerators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1999. Proceedings of the 1999
  • Conference_Location
    New York, NY
  • Print_ISBN
    0-7803-5573-3
  • Type

    conf

  • DOI
    10.1109/PAC.1999.795623
  • Filename
    795623