• DocumentCode
    345521
  • Title

    Vertical emittance in the KEK accelerator test facility

  • Author

    Hirose, T. ; Okugi, T. ; Takayama, Y. ; Hayano, H. ; Kamada, S. ; Kubo, K. ; Naito, T. ; Urakawa, J. ; Kashiwagi, S. ; Takano, M. ; Minty, M. ; Turner, J. ; Woodley, M. ; Zimmermann, F.

  • Author_Institution
    Tokyo Metropolitan Univ., Japan
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    256
  • Abstract
    We applied three methods in order to measure the vertical emittance of KEK-ATF. The first is a SR interferometer, the second method is the emittance measurement by using wire scanners at the beam extraction line. The last method is emittance estimation by measuring an intensity dependence of a momentum spread, which is caused by the intra-beam scattering. The measured vertical emittance for KEK-ATF is 0.02-0.06 nm, which is a few times larger than the design target of KEK-ATF
  • Keywords
    electron accelerators; particle beam diagnostics; storage rings; KEK accelerator test facility; beam extraction line; emittance measurement; intra-beam scattering; synchrotron radiation interferometer; vertical emittance; wire scanners; Colliding beam devices; Damping; Dispersion; Distribution functions; Life estimation; Particle beams; Particle scattering; Strontium; Testing; Wire;